Skip to content

absorption

pd-neut-cwl pd-xray

mu_r

Access Source
absorption.mu_r code
_absorption.mu_r Edi
_easydiffraction_absorption.mu_r coreCIF

Linear absorption coefficient times the sample radius, μR (dimensionless). Only present for type = 'cylinder-hewat'. It is normally entered as a known, fixed value, since it is strongly correlated with the displacement parameters and the scale. The Hewat expansion is validated to four decimals for μR ≲ 1.5; larger values are still computed but emit a warning.

type

Access Source
absorption.type code
_absorption.type Edi
_easydiffraction_absorption.type coreCIF

Active absorption correction type. One of none (no correction) or cylinder-hewat (cylindrical Debye–Scherrer, Hewat model). Use experiment.absorption.show_supported() to list the types available for the current experiment. This category is available for constant-wavelength Bragg powder experiments.